Model 5081 pH & ORP 2-Wire Loop-Powered Transmitter & Analyzer
- The Transmitter has a rugged, weatherproof , corrosion-resistant enclosure.
- NEMA 4X and IP65 of epoxy-painted aluminum.
- This enclosure also meets NEMA 7B explosion-proof standards.
- 24V DC Operation Standard, 12 V minimum and 42.4 maximum.
- Continous Diagnostics monitor sensor performance and warns of failure (FAULT) or approaching failure (WARNING).
- CE Certification for Class I, Division I Areas and FM group A-G.
- Automatic Two-Point Buffer Calibration reduces errors.
- Choice of Communication Protocol: HART® or Foundation Fieldbus.
- Non-Volatile Memory retains program settings and calibration data during power failures.
- Solution Temperature Compensation converts measured pH into the pH at 25°C.
Measurement | Input | Measurement Range | Outputs | Calibration Points | Compatible Sensor(s) | Special Features |
pH/ORP | Single or Dual Channel – pH/ORP |
– 0 to 14 pH (standard) – Fully Scalable from 1 to 13 pH units |
– Analog 0-20 mA or 4-20 mA output for pH/ORP/ISE or temperature for each input channel – Optional HART or ProfiBUS Digital Outputs |
– 2 point auto buffer recognition for pH for slope determination – 1 point user defined pH standardize calibration to correct for offset (drift) |
– Any Suitable ASTI pH/ORP Sensor with 100 or 1000 Ohm Platinum TC – Any Suitable ASTI pH/ORP Sensor with 100 or 1000 Ohm Platinum TC & 1056 compatible preamplifier |
– Excellent option for severe service pH & ORP measurement in areas with flammable gas and corrosive environments. |
Contacting Conductivity | Single or Dual Channel – Conductivity Cell |
– Cell from 0.01 to 10.0, user selectable – Ranges from 0-200 microSiemens (0.01/cm) to 0-200 milliSiemens (10.0/cm) as mates with cell |
– Analog 0-20 mA or 4-20 mA output for Conductivity or temperature for each input channel – Optional HART or ProfiBUS Digital Outputs |
– Zero Calibration (Capitance) – Cell Constant calibration tofFind exact effective (apparent) cell constant in standard solution or process media |
– Any Suitable Contacting Conductivity Sensor with 1000 Ohm Platinum TC | – Support for displaying in concentration units of acids, bases and electrolytes as well as salinity – Special ultrapure water temperature compensation and support for display in resistivity units |
Toroidal Conductivity (Contactless Inductive) | Single or Dual Channel – Toroidal Conductivity Sensor |
– Range from 0.050 to 2,000 milliSiemens (2 Siemens) | – Analog 0-20 mA or 4-20 mA output for Conductivity or temperature for each input channel – Optional HART or ProfiBUS Digital Outputs |
– Zero Calibration (Capitance) – Cell Constant calibration to find exact effective (apparent) cell constant in standard solution or process media |
– Any Suitable Toroidal Conductivity Sensor with 20/20 Windings and 1000 Ohm Platinum TC | – Support for displaying in concentration units of acids, bases and electrolytes as well as salinity – Excellent choice for strong acid, strong base and strong electrolyte solutions at elevated temperatures |